A laboratory process needs more than a stand-alone spin coater
In semiconductor, MEMS, photonics, advanced-packaging and microfabrication R&D, coating must be selected together with substrate geometry, material behavior, thermal steps, development and rinse/dry requirements. SAWATEC individual modules and linked systems support a path from early recipe work to repeatable small-batch processing without forcing every laboratory into the same automation architecture.
Choosing a benchtop spin coater for a research laboratory
For manual photoresist spin coating on flat samples, start by checking the SAWATEC SM-150: a bench-top or bench-mounted tool for wafers up to 150 mm. Small chips require a suitable vacuum chuck and centering method; wafer capacity alone does not define the smallest usable sample.
For 200 mm wafers or dynamic dispensing, compare the SM-200 in the equipment table below. Add a separate hotplate where the resist process needs baking, and select spray coating where deep cavities or steep topography require a different deposition method.
Public SM-150 equipment records from EPFL and Politecnico di Milano document research use. These records support the model and application context; the intended chemistry and sample still need configuration review.
Select the coating path from the real substrate
Spin coating for planar samples
For flat or low-topography wafers and square substrates, control dose, speed, acceleration, exhaust and chuck conditions as one recipe.
Spray coating for 3D structures
Deep cavities, high steps and sidewalls require the sample cross-section, target coverage, nozzle, path, flow and substrate temperature.
Development, rinse and dry
Resist, developer chemistry, spray or puddle mode, rinse media and drying criteria determine the SMD or batch SRD path.
Build an expandable laboratory process flow
Early process work can use independent bench-top or cabinet modules for coating, bake, cooling and development. A Duo combination reduces footprint and manual movement by integrating a coater or developer with a hotplate. When recipes stabilize and sample volume grows, ROBO or CS architectures can link coating, spray coating, development, hotplate and coolplate modules.
1. Prove the process
Define substrate geometry, topography, material viscosity, film target, bake profile and development method before choosing the machine.
2. Stabilize the recipe
Bring dispense, speed, acceleration, bake, cooling, development, rinse and dry steps into a repeatable sequence.
3. Expand automation
Use throughput, footprint, transfer consistency and future module needs to choose Duo, ROBO or cluster automation.
Laboratory equipment paths
| Process need | Equipment path | Published substrate range | Configuration focus |
|---|---|---|---|
| Manual spin coating and recipe work | SM-150 laboratory benchtop spin coater | Up to 150 mm wafers or 127 × 127 mm substrates | SAWATEC SM-150 is a standalone manual spin coater for laboratory photoresist thin-film coating and recipe development on wafers up to 150 mm (6 inches) or square substrates up to 127 × 127 mm. It can be installed on a bench or table. See the SAWATEC SM-150 manufacturer specifications. |
| Semi-automated coating and multiple liquid lines | SM-200 | Up to 200 mm wafers or 150 × 150 mm substrates | SAWATEC SM-200 is a standalone semi-automatic spin coater for laboratory photoresist spin coating on wafers up to 200 mm (8 inches) or square substrates up to 150 × 150 mm. It features an RCCT chamber, dynamic dispense arm and configurable liquid delivery. See the SAWATEC SM-200 manufacturer listing. |
| Semi-automatic spin coating on 12-inch wafers | SAWATEC SM-300 | Up to 300 mm wafers | SAWATEC SM-300 is a standalone semi-automatic spin coater for photoresist thin-film coating on wafers up to 300 mm (12 inches) in laboratories and R&D. See the SAWATEC SM-300 manufacturer specifications. |
| Deep cavities and high steps | iSPRAY-300 | Up to 300 mm wafers or 12 × 12 inch substrates | SAWATEC iSPRAY-300 is a standalone photoresist spray coater for laboratory work on three-dimensional microstructures, including deep cavities and high steps. It supports wafers up to 300 mm and square substrates up to 12 × 12 inches. SAWATEC iSPRAY-300 applications and substrate specifications. |
| Standalone laboratory spray development and cleaning | SAWATEC SMD-200 | Up to 200 mm wafers or 150 × 150 mm substrates | SAWATEC SMD-200 is a standalone semi-automatic laboratory developer for photoresist spray development and cleaning on wafers up to 200 mm (8 inches). For cassette-to-cassette processing, SAWATEC lists the SMD-200-CS as a development station within the CS-200-4 sirius cluster. See the manufacturer’s standalone SMD-200 specifications, which list the puddle development nozzle as an option, and the Shanghai Jiao Tong University SMD-200 equipment record. |
| Automated wafer development within a cluster system | SAWATEC SMD-200-CS | Up to 200 mm wafers in the CS-200-4 sirius system | SAWATEC SMD-200-CS is the photoresist development module in the SAWATEC CS-200-4 sirius automated cassette-to-cassette system for wafer spin coating, development and baking. See the manufacturer’s CS-200-4 sirius module configuration. |
| Standalone laboratory spray development up to 12 inches | SAWATEC SMD-300 | Up to 300 mm wafers or 200 × 200 mm substrates | SAWATEC SMD-300 is a standalone semi-automatic tool for photoresist spray development and cleaning in laboratory and R&D workflows. It supports wafers up to 300 mm (12 inches) or square substrates up to 200 × 200 mm. See the manufacturer’s SMD-300 specifications. |
| Development, cleaning and optional wet etching | SAWATEC SMD-200-E | Up to 200 mm wafers or 150 × 150 mm substrates | SAWATEC SMD-200-E is a standalone semi-automatic system for laboratory photoresist spray development and cleaning on wafers up to 200 mm (8 inches). This configuration also supports wet etching. See the manufacturer’s SMD-200-E configuration. |
| Standalone photoresist baking | SAWATEC HP-150 | Up to 150 mm wafers | SAWATEC HP-150 is a standalone laboratory hotplate for soft baking and hard baking photoresist on wafers up to 150 mm (6 inches). See the SAWATEC HP-150 manufacturer specifications. |
| Standalone photoresist baking | SAWATEC HP-200 | Up to 200 mm wafers | SAWATEC HP-200 is a standalone laboratory hotplate for soft baking and hard baking photoresist on wafers up to 200 mm (8 inches). See the SAWATEC HP-200 manufacturer specifications. |
| Photoresist baking with individual zone control | SAWATEC HP-200-Z | Confirm wafer diameter, thickness and loading method with the manufacturer | The SAWATEC HP-200-Z hotplate provides nine independently adjustable heating zones for laboratory lithography and MEMS soft baking and hard baking. The standard temperature range extends to 300 °C. See the manufacturer’s HP-200-Z specifications. |
| Standalone photoresist baking | SAWATEC HP-300 | Up to 300 mm wafers | SAWATEC HP-300 is a standalone lithography hotplate for soft baking and hard baking photoresist on wafers up to 300 mm (12 inches). See the SAWATEC HP-300 manufacturer specifications. |
| Compact development plus baking | SAWATEC SMD-200/HP-200 Duo | Up to 200 mm wafers or 150 × 150 mm substrates | SAWATEC SMD-200/HP-200 Duo combines a spin developer and a hotplate in one cabinet for laboratory and R&D workflows. It supports spray or puddle photoresist development, cleaning, and soft or hard baking on wafers up to 200 mm (8 inches) or square substrates up to 150 × 150 mm. See the manufacturer’s SMD-200/HP-200 Duo specifications. |
| Spin coating and baking for 6-inch wafers | SAWATEC SM-150/HP-150 Duo | Up to 150 mm wafers or 127 × 127 mm substrates | SAWATEC SM-150/HP-150 duo combines photoresist spin coating and hotplate soft bake or hard bake in one cabinet for laboratory lithography. Its spin coater supports wafers up to 150 mm (6 inches) or square substrates up to 127 × 127 mm. See the SAWATEC SM-150/HP-150 duo manufacturer specifications. |
| Spin coating and baking for 8-inch wafers | SAWATEC SM-200/HP-200 Duo | Up to 200 mm wafers | SAWATEC SM-200/HP-200 duo combines semi-automatic photoresist spin coating and hotplate soft bake or hard bake in one cabinet for laboratory lithography on wafers up to 200 mm. See the SAWATEC SM-200/HP-200 duo manufacturer specifications. |
Six inputs needed before configuration
Substrate
Shape, dimensions, thickness, weight, warpage and backside condition.
Topography
Flat surface, high steps, deep cavities, sidewalls or a three-dimensional structure.
Material
Resist or coating name, viscosity with temperature, solvent and target film.
Process route
Spin or spray, thermal steps, development, rinse, dry and cleaning sequence.
Volume
Samples per batch, takt time, recipe changes and expected growth.
Facilities and acceptance
Utilities, footprint, safety boundary, representative sample and pass/fail method.
Start the laboratory configuration from the process
Send the substrate drawing, material data, target result, process sequence and sample volume. These inputs narrow the coating, bake, develop, liquid-path and automation scope.